Overview
Imaging supports acquisition of 3D CAD/CAM scans from DEXIS IS ScanFlow via software bridge.
📝 Please note: The Imaging Acquisition Agent should be installed prior to any Imaging device installs (i.e. Install the Acquisition Agent before setting up DEXIS IS ScanFlow software bridge below) and must be installed on each client workstation that will acquire images from the DEXIS IS ScanFlow software bridge. The Imaging Acquisition Agent has an installer and an associated document covering its installation.
📝 Please note: DEXIS IS ScanFlow must be installed locally. DEXIS-supported intraoral scanner devices may be used through the ScanFlow application.
Recommended version
DEXIS IS ScanFlow version: 2.0 (2.0.2.902) or later
Minimum version
Acquisition agent version: 1.188.0 or later
DEXIS IS ScanFlow version: 2.0 (2.0.2.902) or later
Required setup for DEXIS IS ScanFlow software bridge:
Acquisition agent - DEXIS IS ScanFlow settings:
Right click on the Acquisition Agent and select 'Preferences'
On the Software Bridge tab, select 'Page 2' and fill out the Target Directory field for where your scans will be exported from the DEXIS IS ScanFlow software.
📝 Please note: The Target Directory for the Acquisition Agent and in the DEXIS IS ScanFlow software must be the same for the integration to work.
Testing
The DEXIS IS ScanFlow software bridge will now be functional in the imaging module.
📝Please note: The DEXIS ScanFlow software should be open prior and the user signed in.
In the Imaging Procedures list, select 'CAD/CAM'.
In the device list, select 'DEXIS IS ScanFlow' in the software bridge section.
Start acquisition.
The IS ScanFlow software will automatically open the patient and the scanner will initialise.
After the scanner initializes, you are now ready to acquire images inside of the Dexis IS ScanFlow Software.
The upper jaw will be automatically selected. Use the device to scan the upper jaw, lower jaw, and middle teeth. Under 'Configure Scan', you can adjust settings as needed.
Next, click 'Refine'. This allows you to make any enhancements.
When ready, click 'Export'. Verify that the target directory is the same as the one you setup in Acquisition Agent, and choose a format for the scan to be saved in.
Click 'Export', or 'Export and Exit' to close the DEXIS ScanFlow software. The Images should automatically mount in the RealCloud Imaging Software.
Click 'Begin Uploading' to finish acquisition.
The exam will be created and will be viewable in the exam list.
Troubleshooting
Verify that the DEXIS ScanFlow settings are configured correctly inside of the Acquisition Agent.
For any issues related to a device not working inside of the DEXIS ScanFlow software, please contact DEXIS ScanFlow support.